NS-IS 6

Products
RAID
Enterprise
NAS
SAN
Backup Products
Controllers
JBOD
Accessories
Full product list
Reseller Forms

Products > RAID solutions > RAID IDE

All PDF forms require the free Adobe Acrobat Reader.

Overview

The NS-IS 6 is an Ultra3 SCSI-to-IDE disk array subsystem powered by a sophisticated RAID controller. With advanced fiNS-RM -ware functions as well as 64-bit hardware architecture, data can be easily distributed and processed at raging speed. This enclosure houses 6 IDE drives in Hot-Swappable disk trays. The RAID array can be configured in levels 0, 1 (0+1), 3, or 5. The system allows one HDD failure without impact on the existing data. Failed drive rebuild is transparent to host's running programs and accessing data.

System operation is protected by redundant cooling fans and redundant Power Supplies. Environmental information is accessible either via control panel or through the RAIDGuide Manager. The NS-IS 6 is a cost-effective disk array system with completely integrated high performance and data-protection functions.

• Ultra3 SCSI host interface 160Mbyte/sec transfer rate
• Up to 6 EIDE ATA/UDMA-100 hard disk drives (ATA/UDMA-100 compatible)
• Supports 3.5" x 1" high EIDE drives
• RAID levels: 0, 1 (0+1), 3, 5
• Smooth Hot-Swappable drive tray mechanism
• User-friendly RAIDGuide Manager
• Convenient front LCD control panel
• Redundant and Hot-Swappable Power Supplies
• Redundant cooling fans
• Compact enclosure design

High Performance
The NS-IS 's high performance comes from the 64-bit Power PC CPU and proprietary ASIC. For higher efficiency and more throughput than most small to medium sized servers or workstations, the bandwidth of the 64-bit bus runs at 66 MHz between the SDRAM and the CPU. Data is distributed through a high speed 64-bit path at a burst rate of 533MB/second. The system's overall performance reaches up to 109MB/second and 5480 IO/second nearly equaling the combined performance of all the drives. The dual independent PCI bus design eliminates bandwidth bottlenecks for IO traffic. The balanced bus loading and highly scalable design make the NS-IS an optimal RAID solution for a wide range of SCSI based PC's, single user workstations, NT, Linux and Unix based servers.

High Data Availability
The system provides RAID levels 0, 1 (0+1), 3 and 5. RAID configurations can be managed either through the LCD control panel or by the system-embedded configuration utilities.

Its high data availability and protection derives from the following capabilities: automatic drive failure detection, automatic failed drive rebuilding, hot spare and background rebuild, disk hot swap, and online background rebuilding.

Redundant Power Supplies
Two Hot-Swappable redundant Power Supplies provide zero down time and fault tolerant power. With two Power Supplies installed, both will share the current power needs of the whole system. If one should fail, an alarmwill sound and the remaining power supply will take over the full load until the faulty unit is replaced. The Hot-Swap feature ensures that the system remains operational while replacement is taking place.

Redundant Cooling Fans
Two cooling fans are integrated for redundancy. Failures are displayed by the RAIDGuide manager software.

The system's ventilation is from front to back. Specially designed airflow passages dissipate heat from the hard disks and the controller. Power-supply modules are equipped with their own independent cooling fans.

Setup and Status Monitoring
The system will automatically initialize based on the number of disk drives installed at start up. Manual configuration and monitoring can be done through the LCD control panel. The firmware contains an embedded management program that can be accessed using a terminal connected to the RS-232C port.

RAIDGuide Manager
RAIDGuide, an advanced and user-friendly GUI management program is also available to communicate between the host and the array through a proprietary in-band SCSI protocol. RAIDGuide is a complete management interface to the disk array. Users may view the status of all the connected drives, enclosure components, and controller board at a glance. The GUI design makes maintenance of the enclosure a simple matter of point and click.

Controller
PowerPC-603e 100MHz RISC processor
Standard 32MB cache memory on one
SODIMM SDRAM; Other available cache sizes: 64/128/256MB
2 independent 33MHz 32/64-bit PCI buses
Firmware in Flash ROM for easy upgrades

RAID Operation
RAID level 0, 1 (0+1), 3 and 5
Hot spare drive operation
Drive Hot-Swapping
Automatic background rebuild
Online drive expansion

Drive Interface
EIDE ATA-66/UDMA-66 (ATA-/UDMA-100 compatible; and fully backward compatible with earlier ATA and UDMA standard drives)
6 Hot-Swap drive bays and trays
Supports 1-inch height foNS-RM factor

Host Interface
Ultra3-Wide LVD SCSI
Transfer rate up to 160Mbps/
Concurrent I/O command
Tagged Command Queuing
Automatic bad-sector reassignment
Up to 12m cable length

Controls / Indicators
Front LCD control panel for setup and configuration
3 drive LED indicators: power, busy, attention
Power and drive failure indication through LCD
Built-in alarm

Management Software
RAIDGuide manager software for Windows 2000 / NT via in-band SCSI
Firmware embedded manager via RS-232C (platformindependent)

Physical / Electrical Interfaces One 68-pin, single-ended or differential SCSI connector DB-9 RS-232C serial port (38400, n, 8, 1) for terminal connection

Power Supply 2 redundant Hot-Swappable Power Supplies 90 to 265VAC, 47 to 63 Hz @12V (14A max.), 5V (16A max.), 250Watts

Cooling Fans 2 cooling fans in two separate modules, ball bearing, 12V, 0.3A, 2850rpm, 34dbA

Operating Temperature 5 to 40 C

Relative Humidity 10-95%, non-condensing

Altitude Sea level to 10,000 ft

Dimensions 13.8H x 6.8W x 12.9D inches

Download the printable PDF!

back to top


Please contact our sales team at info@networksynthesis.com if you want to find out more!