Electrical
AC Input Power
Voltage: 90/230VAC ± 15% (switch selectable)
Frequency: 50 to 60Hz
Protection: 10A/250V fuse
Efficiency: PFC function
DC Output Power
(Three units, load-sharing)
Continuous: 300W each, 900W total
Environmental
Temperature
Operating: 5 to 40° C
Storage: -40 to 60° C
Humidity
10 to 90%, non-condensing
Altitude
Operating: 0 to 10,000 feet
Storage: 0 to 30,000 feet
Physical
Installation
Rackmount configuration
Dimensions
17.5"w 19"d x 5.25"h (3U)
Weight
66Lbs (w/o disk drives)
Configuration
Drive Trays
Fourteen 3.5 x 1 inch low profile Fibre drive trays
Power Supplies
Three 300W Power Supplies with PFCs
Cooling
• Two fan modules provide front to rear cooling
• Dual fans within individual Power Supplies
• All-metal construction with aluminum drive trays
Access
Peripherals
Fast-disconnect trays - Hot-Swappable
Power Supplies
Mounted on rear panel, secured by captive screws - Hot-Swappable
Fans Mounted
on rear panel, secured by captive screws - Hot-Swappable
Fault Indicators
Drive Power
Amber LED - access, Red LED - error, Green LED - online
Power Supplies
Red LED on front of enclosure and audible alarm, LEDs
on each power supply module identifying specific failed
power supply
Fans LEDs
on front panel and audible alarm