NS-RC 2000

Products
RAID
Enterprise
NAS
SAN
Backup Products
Controllers
JBOD
Accessories
Full product list
Reseller Forms

Products > Controllers

All PDF forms require the free Adobe Acrobat Reader.

Fibre-Fibre RAID Controllers

Overview
The NS-RC 2000 is the performance champion among RAID controllers. Powered by a high-performance 64-bit RISC PowerPC CPU and dual Infortrend sophisticated RAID ASICs, I/Os are rapidly processed and distributed to array hard drives. Data is transferred between host and drive through a high-speed 64-bit data path at a burst rate of 533MB/sec. The result is a controller which excels in applications that require high sustained data rates and I/O turnaround.

High Flexibility
All Fibre channels are configurable as either host or drive in single or dual loop configuration. The active-active configurations via single or multiple host ports allow the optimal connectivity in a multi-host environment. The Workload over dual-loop paths can be automatically adjusted through intelligent optimization algorithms.

Firmware upgrade does not affect the redundant configuration of controllers. Controllers can shift I/Os temporarily to allow both firmware to be updated. In the event of the unlikely controller failure, a failed controller can be replaced with one running later version of firmware.

Sync. Cache over Fibre Channels
Besides SCSI channels, the intercontroller communications can be NS-RC 2000R configured as using one or two dedicated Fibre channels or sharing with all drive 6 Fibre Redundant loops together. The communications Channels traffic can be automatically balanced between or among loops. Should one communications path fail, the existing channel(s) will continue its work.

SAN Application
The NS-RC 2000 has all the necessary protocols for SAN applications. This includes the capabilities for operation in a multi-host and multi-platform environment such as LUN filtering (also known as SAN mapping or masking), active-active failover /failback, and partitioning of multiple-level RAID array. 64 array partitions and 128 filter entries per controller are supported.

High Data Availability
With a multitude of RAID functions, the user gets the highest data availability and security. The NS-RC 2000’s capabilities include automatic drive failure detection, concurrent background rebuilding, and bad sector reassignment; all without affecting host access.

Active-Active Redundancy
The NS-RC 2000 supports active-active redundancy with a synchronized writeback cache. Integrators can choose the two dedicated SCSI channels or Fibre channel(s) as the cache synchronization paths. In redundant mode, a failed controller automatically shifts I/O functions to the existing controller, and the controller failover/failback process is totally transparent to the host. The controller itself is hot-swappable for full non-stop redundant operation. A faulty controller can easily be ejected from the front.

The optional battery backup protects any data cached in memory from sudden power interruptions.

Board-Only Solutions for OEMs
The NS-RC 2000 controller is an ideal solution for OEM customers who design their own backplanes. The controller board can be readily integrated with a cable-less and hot-swappable enclosure design.

Redundant Chassis (2000R)
The 2000R series consists of two controllers in a 5.25" full-height chassis. All signal paths, including two dedicated communications channels, are routed on the back panel of the solution for path redundancy and cache synchronization. Bypass circuits are included to maintain loop integrity providing fabric connectivity and also the freedom of controller hot-replacement. The cableless design makes system integration effortless.

Download the printable PDF

back to top

Please contact our sales team at info@networksynthesis.com if you want to find out more!